SNMPWALK
Example 2-10. Sample SNMPWALK Output
TACL> SNMPWALK -d 3 -a $zsnmp1 \mynode sysDescr.0
------ RUNNING LOCAL ------
SENDING PACKET:
Packet Length=69, Version=0, Community: Length=6, Value=public
PDU Type=get-next-request Length=69, RQ_ID=1, Err_stat=noError, Err_ndx=0
VBLlen=43, VBcount=1
VarBind #0, content size=43, Flags & type=0x05, encoded length=5
OBJECT IDENTIFIER: sysDescr.0
NULL
RECEIVED PACKET:
Packet Length=94, Version=0, Community: Length=0, Value=
PDU Type=get-response Length=94, RQ_ID=1, Err_stat=noError, Err_ndx=0
VBLlen=84, VBcount=1
VarBind #0, content size=79, Flags & type=0x06, encoded length=40
OBJECT IDENTIFIER: sysObjectID.0
OBJECT IDENTIFIER: 1.3.6.1.4.1.169.3.155.1
SENDING PACKET:
Packet Length=63, Version=0, Community: Length=0, Value=
PDU Type=get-next-request Length=63, RQ_ID=2, Err_stat=noError, Err_ndx=0
VBLlen=43, VBcount=1
VarBind #0, content size=43, Flags & type=0x05, encoded length=5
OBJECT IDENTIFIER: sysObjectID.0
NULL
RECEIVED PACKET:
Packet Length=56, Version=0, Community: Length=0, Value=
PDU Type=get-response Length=56, RQ_ID=2, Err_stat=noError, Err_ndx=0
VBLlen=46, VBcount=1
VarBind #0, content size=43, Flags & type=0x43, encoded length=4
OBJECT IDENTIFIER: sysUpTime.0
TimeTicks: 59101
SENDING PACKET:
Packet Length=63, Version=0, Community: Length=0, Value=
PDU Type=get-next-request Length=63, RQ_ID=3, Err_stat=noError, Err_ndx=0
VBLlen=43, VBcount=1
VarBind #0, content size=43, Flags & type=0x05, encoded length=5
OBJECT IDENTIFIER: sysUpTime.0
NULL
RECEIVED PACKET:
Packet Length=61, Version=0, Community: Length=0, Value=
PDU Type=get-response Length=61, RQ_ID=3, Err_stat=noError, Err_ndx=0
VBLlen=51, VBcount=1
VarBind #0, content size=46, Flags & type=0x04, encoded length=7
OBJECT IDENTIFIER: sysContact.0
OCTET STRING: Length=7
Unknown