SPI Common Extensions Manual
ZCOM Errors
SPI Common Extensions Manual—427508-001
A-23
–25 ZCOM-ERR-SUB-NOT-FOUND (warning)
subsys-type-name
represents any number of subsystem-defined tokens described in the subsystem-
specific management programming manual.
Cause. The SSID specified in the call to SSINIT is not a recognized ID.
Effect. The command is canceled.
Recovery. Correct the SSID and reissue the request.
–25 ZCOM-ERR-SUB-NOT-FOUND (warning)
A command contained the SUB modifier, but no subordinate objects were found.
This error applies only when the SUB modifier is set to the SUB-ONLY value or the
value of a specific object type. This error is not issued in response to a command
containing a SUB modifier set to SUB-ALL.
ZCOM-TKN-OBJNAME
contains the name of the parent object and is included if relevant to the analysis of
the error condition.
ZCOM-TKN-OBJTYPE
specifies the object type (ZCOM-OBJ-objtype) of the parent object and is
included if relevant to the analysis of the error condition.
subsys-type-name
represents any number of subsystem-defined tokens described in the subsystem-
specific management programming manual.
Cause. The specified command object has no subordinates.
Effect. The command is not applied to any subordinates of the command object.
Recovery. No recovery is necessary. This message is informative only.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
subsys-type-name token-type subsys-defined
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL