SPI Common Extensions Manual

ZCOM Errors
SPI Common Extensions Manual427508-001
A-34
–38 ZCOM-ERR-PWR-WEAK-FOR-COND (error)
–38 ZCOM-ERR-PWR-WEAK-FOR-COND (error)
The value specified for the ZCOM-TKN-CMD-POWER command modifier is too weak
for the command to affect an object in its current condition.
This error is issued only when the command power modifier is included in the
command buffer, and some condition other than the object’s summary state is the
limiting factor. If the object’s summary state prevents the command from being applied,
the error ZCOM-ERR-PWR-WEAK-FOR-SUMSTATE is issued instead.
ZCOM-TKN-OBJNAME
contains the name of the object to which the command could not be applied and is
always included in the error list for this error.
ZCOM-TKN-OBJTYPE
contains the type (ZCOM-OBJ-objtype) of the object to which the command
could not be applied and is always included in the error list for this error.
subsys-type-name
represents any number of subsystem-defined tokens described in the subsystem-
specific management programming manual.
Cause. The command power is inadequate given the current condition of the
command object.
Effect. The command is not applied to the object.
Recovery. Recovery depends on whether it is acceptable to escalate the value of the
modifier.
–39 ZCOM-ERR-CMD-NOT-SUPP-BY-OBJ (error)
A command otherwise valid for objects of the specified type cannot be applied to a
particular object.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
subsys-type-name token-type subsys-defined
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
subsys-type-name token-type subsys-defined
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL