SPI Common Extensions Manual
ZCDG Definitions
SPI Common Extensions Manual—427508-001
C-2
ZCDG Data Definitions
ZCDG-TKN-ASYNC-SET-CONFIG-PARM
ZCDG events include this token to convey a controller microcode configuration
message. The message is described in the controller or IOP documentation.
ZCDG-TKN-ASYNC-VFU
This token contains the data programmed to a printing device’s vertical formatting unit
(VFU).
ZCDG-TKN-BOB-SENSE
This token conveys the value of the breakout board (BOB) power supply.
ZCDG-TKN-BOB-SRC
This token identifies the breakout board (BOB) source. Valid values and their meanings
are:
token-code ZCDG-TKN-ASYNC-SET-CONFIG-PARM
value ZCDG-TNM-ASYNC-SET-CONFIG-PARM
token-type ZSPI-TYP-BYTESTRING
heading "Async-Task-Config-Message".
token-code ZCDG-TKN-ASYNC-VFU
value ZCDG-TNM-ASYNC-VFU
token-type ZCDG-TYP-ASYNC-FUNC
heading "VFU-Data".
token-code ZCDG-TKN-BOB-SENSE
value ZCDG-TNM-BOB-SENSE
token-type ZSPI-TYP-INT
heading "BOB's Power Supply".
token-code ZCDG-TKN-BOB-SRC
value ZCDG-TNM-BOB-SRC
token-type ZSPI-TYP-ENUM
heading "BOB-Source".
ZCDG-VAL-BOB-SRC-ADC-CONV ADC conversion error
ZCDG-VAL-BOB-SRC-CLB-FRAME-ORN CIU-LIU bus (CLB) RCV frame queue overflow
ZCDG-VAL-BOB-SRC-CLB-MUX CLB multiplexor error
ZCDG-VAL-BOB-SRC-CMD-SW-CHECK Command decode software check
ZCDG-VAL-BOB-SRC-DMT-EXPIRE Deadman timer expired
ZCDG-VAL-BOB-SRC-EPROM-XSUM BOB’s EPROM checksum error
ZCDG-VAL-BOB-SRC-FAN-FAIL Fan failure