C-39
–10027 ZCDG-EVT-CLIP-ERR
–10027 ZCDG-EVT-CLIP-ERR
An error on a CLIP was detected.
ZEMS-TKN-EVENTNUMBER
has the value ZCDG-EVT-CLIP-ERR.
ZCDG-TKN-CLIP-STATUS
contains the CLIP status byte.
Cause. The CLIP responded to the IOP with an invalid function modifier. There might
be a hardware or software fault.
Effect. Communication is interrupted.
Recovery. Stop and reload the CLIP. If the problem persists, run loopback tests.
–10028 ZCDG-EVT-CLIP-SUB-ERR
A subdevice error was detected.
ZEMS-TKN-EVENTNUMBER
has the value ZCDG-EVT-CLIP-SUB-ERR.
Tokens in Event Message
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-MARK
ZCOM-TKN-SUBJ-objtype token-type ZSPI-TYP-STRING
ZEMS-TKN-LDEVNAME <1> token-type ZSPI-TYP-FNAME32
ZCDG-TKN-CLIP-STATUS <2> token-type ZSPI-TYP-INT
Message Text
A CLIP error has been detected on <1>
CLIP Status: <2>
Tokens in Event Message
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-MARK
ZCOM-TKN-SUBJ-objtype token-type ZSPI-TYP-STRING
ZEMS-TKN-LDEVNAME <1> token-type ZSPI-TYP-FNAME32
ZCDG-TKN-SUBDEV-NUM <2> token-type ZCDG-TYP-SUBDEV-NUM
ZCDG-TKN-CLIP-STATUS <3> token-type ZSPI-TYP-INT
Message Text
A subdevice error has been detected on <1>
Subdevice Number: <2>
CLIP Status: <3>