Spooler Plus Programmer's Guide
Spooler-Related Errors
Spooler Plus Programmer’s Guide—522293-003
C-5
File-System Errors
Cause. The collector is not accepting open requests. This error can occur for the 
following reasons:
The system operator brought down the specified device.
A hard error occurred on the device controller.
The spooler collector process sent a spooled job to a nonmirrored disk.
Both halves of a mirrored disk are down.
Effect. A Spoolcom user has issued a SPOOLER DRAIN command. The collector 
finishes accepting any jobs that were open when the command was issued, but no new 
jobs can start.
Recovery. The same Spoolcom user must issue a SPOOLER START command.
Cause. This error can occur for the following reasons:
The device was not powered up or is not online.
A printer is out of paper or is not working.
A card reader is out of cards.
A tape drive is accessed while rewinding.
A tape drive is at a load point but is not online.
A heavily loaded processor receives a call to open a server process but cannot 
respond.
Effect. The procedure sets the error code and returns without performing the 
requested operation.
Recovery. Make the device ready. In the case of a heavily loaded processor, repeat 
the call to open the process.
Cause. A printer could not continue because it was out of paper or because the paper 
bail was not in place.
Effect. The procedure sets the error code and returns without performing the 
requested operation.
 66 (%102) DEVICE DOWNED, LIU NOT YET DOWNLOADED,
 OR HARD FAILURE OCCURRED ON CONTROLLER
100 (%144) DEVICE NOT READY OR CONTROLLER NOT
 OPERATIONAL
 (device type: any except 2)
102 (%146) PAPER OUT, BAIL OPEN, OR END OF RIBBON