Spooler Plus Utilities Reference Manual
Spoolcom
Spooler Plus Utilities Reference Manual—522294-002
3-29
DEV Command
RETRY interval
specifies the number of seconds a print process waits before retrying an I/O
operation that has failed because of a retryable I/O error. The valid range for
interval is 1 through 32767. The default value is 5 seconds.
Use RESTART to specify the action to be taken for a nonretryable I/O error.
Use RETRY and TIMEOUT to specify the action to be taken for a retryable I/O
error.
SKIP [ + | - ] number-of-pages
causes the device to skip ahead or skip back number-of-pages relative to
the current page. A minus sign (-) indicates skipping backward; no sign or a
plus sign (+) indicates skipping forward. The device starts printing at the first
line on the new page. The range of values for number-of-pages is -32767
through +32767. Users who are not a system operator (user ID 255, n) can
execute this subcommand only on their own jobs.
SKIPTO page-number
causes the device to skip to the indicated page. The range of values for
page-number is 1 through 65500 pages. Users who are not system
operators (user ID 255, n) can execute this subcommand only on their own
jobs.
SPEED lines-per-minute
allows you to specify the estimated printing speed of the device. This
subcommand is used for calculating how long a job takes to print. It has no
effect on the actual speed of the device. The range of values for lines-per-
minute is 1 through 32767. If not specified, a default speed of 100 is
assumed.
Table 3-7. Retryable Error Numbers
Retryable Error
Number Description
12 file in use
100 device not ready
102 paper out
140 modem error
218 interrupt timeout