Spooler Plus Utilities Reference Manual

RPSetup Utility
Spooler Plus Utilities Reference Manual522294-002
5-16
ASSIGN and PARAM Commands
PARAM PRIORITY
The PARAM PRIORITY command sets the priority of the print process that controls the
interspooler threads. This command is equivalent to the SPOOLCOM command
PRINT PRI.
execution-priority
is the execution priority. The value can be in the range 1 through 199. The default
value is the priority of the local spooler supervisor minus 10.
PARAM THREADNAME
The PARAM THREADNAME command sets the generic portion of the device name for
an interspooler thread. This configuration parameter applies individually to all
interspooler threads. You can use the command to override the entire DEV name,
specified through the Spoolcom DEV Command, including the remote collector name.
You can also use this parameter to override the #qualifier.name portion only.
name
is a device name. The default name is the first active collector in the
IN remote-spooler parameter of the RPSetup command with the following added:
#XFER.THREADnn, where nn is a number in the range 01 through 99 assigned by
RPSetup to indicate the ordinal number of the thread.
PARAM PRIORITY execution-priority
PARAM THREADNAME name