SQL/MP Messages Manual
SQL Catalog Manager Messages (1000 to 1999)
HP NonStop SQL/MP Messages Manual—427720-006
3-87
SQL 1561
Cause. While attempting to obtain the node name associated with the current user to
check for Safeguard user defaults, the GETSYSTEMNAME procedure reported an
error.
Effect. The statement fails.
Recovery. Reissue the statement. If it fails again, report the entire message to your
service provider.
SQL 1562
Cause. The catalog manager constructed an incorrect SMP process name while
attempting to retrieve security information for the current user or SQL object.
Effect. The statement fails.
Recovery. None. Report the entire message to your service provider.
SQL 1563
Cause. The VERSIONS table was not found in the specified subvolume.
Effect. The statement fails.
Recovery. If the location is incorrect, reissue the command and supply the correct
location. If the catalog does not exist, create the catalog. If an entry already exists in
$SYSTEM.SQL.CATALOGS for the catalog, use CLEANUP to remove it and then
create the catalog. If some of the tables that make up a catalog exist in the subvolume,
use CLEANUP.
1561 Unable to access system number value-1 to check
Safeguard user defaults for user value-2. The GETSYSTEMNAME
procedure returned error #value-3.
1562 value-1 is not a valid name for a process. The process
name constructed for communication with the Safeguard
subsystem is incorrect.
1563 The catalog (value-1) does not exist.