SQL/MP Messages Manual

SQLCI Utility Processor Messages (9000 to 9999)
HP NonStop SQL/MP Messages Manual427720-006
11-49
SQL 9164
Cause. The NEXT-OBJ number in DICTDDF exceeded the unsigned 32-bit range.
The dictionary is full and no more objects can be added.
Effect. DDL closes the dictionary and output files and stops processing.
Recovery. Delete some objects from the dictionary and recompile.
SQL 9165
Cause. The collation source information could not be retrieved from the CPRLSRCE
catalog table. See the file system error following this error for more information.
Effect. The command fails.
Recovery. Correct the file system error condition.
SQL 9166
Cause. The SECURE function could not retrieve information from the catalog in which
the collation object is registered.
Effect. If the error limit in the ALLOWERRORS option is reached, the command
terminates.
Recovery. See the message following this error for recovery.
9164 The ENSCRIBE dictionary value-1 is full and no more
objects can be added. The sequence number used in the
dictionary has exceeded the unsigned 32-bit range.
9165 An error occurred when extracting the collation value-1
source from the CPRLSRCE catalog table.
9166 Unable to access the catalog that collation object
value-1 is registered in. See the message following this for