SQL/MX 2.x Messages Manual (G06.24+, H06.03+)

Utility Messages (20000 through 23099)
HP NonStop SQL/MX Messages Manual523730-004
17-11
Effect. The operation fails.
Recovery. Check the spelling of the specified table name and resubmit.
SQL 20037
Cause. You specified a request that was not ADD, DROP, MOVE, or REUSE.
Effect. The operation fails.
Recovery. Check the spelling of your request and resubmit.
SQL 20038
Cause. You specified a key value with incorrect syntax.
Effect. The operation fails.
Recovery. Check the syntax of the specified partitioning key value and resubmit.
SQL 20039
Cause. You used the add-move-boundary-range syntax instead of partition-
identification to identify a partition to be moved, dropped, or reused, but you did
not specify the exact partition range.
Effect. The operation fails.
Recovery. Reissue the request with the correct partition range. Consider using the
partition-identification syntax instead.
SQL 20040
Cause. The utility subsystem that retrieves data from the file system failed because no
file name was specified to the subsystem.
Effect. The operation fails.
Recovery. None. This is an internal error. Contact your service provider.
20037 An invalid operation was specified - only ADD, DROP,
and MOVE are supported.
20038 The specified key value uses incorrect syntax.
20039 For the MOVE, DROP, and REUSE requests, the key range
must specify an exact partition range.
20040 An internal error occurred - file name not specified
while getting file label information.