SQL/MX Connectivity Service Manual (SQL/MX 2.x)
Starting, Configuring, and Managing MXCS
HP NonStop SQL/MX Connectivity Service Manual—524944-008
3-26
Configuring Data Source Attributes for SequeLink
In this example, the attributes CATALOG and SCHEMA for data source ATC_TESTS
are defined as “cat” and “sch”, which are case sensitive names.
[ODBC]
TraceStart = 0
TraceFile = ddlog
TraceFlags = 6
[ODBC Data Sources]
TDM_Default_DataSource = NonStop ODBC/MX
ATC_TESTS = NonStop ODBC/MX
DataSourceName = Driver
[TDM_Default_DataSource]
DataLang = 0
Description = Default Data Source
FetchBufferSize = SYSTEM_DEFAULT
Server = FILE:\SYS01.$MXCS
SQL_ATTR_CONNECTION_TIMEOUT = SYSTEM_DEFAULT
SQL_LOGIN_TIMEOUT = SYSTEM_DEFAULT
SQL_QUERY_TIMEOUT = 120
[ATC_TESTS]
Description = Data Source for ATC programs
Catalog = cat
FetchBufferSize = SYSTEM_DEFAULT
Schema = sch
Server = LOCAL:
SQL_ATTR_CONNECTION_TIMEOUT = SYSTEM_DEFAULT
SQL_LOGIN_TIMEOUT = SYSTEM_DEFAULT
SQL_QUERY_TIMEOUT = NO_TIMEOUT
[DataSourceName]
Driver = NonStop ODBC/MX