SSH Reference Manual
EMS Events 
The STN installation subvolume contains standard EMS files which provide additional details: 
•  ZSTNDDL DDL for event names 
•  ZSTNTMPL template output file for EMSDIST 
It is recommended that ZSTNTMPL be installed using standard procedures. 
Note: In the following event descriptions, event name and number are given, followed by the EMS template for this 
event. All references to <1> refer to the STN process that issued the event. 
zstn-evt-stnlog value is 1003 
"<1> STNLOG <2>" 
<2> text 
•  CAUSE: STNLOG messages can be generated by other components and also by the STNCOM command 
STNLOG. The text is described in the documentation for the component which generated the message. 
•  EFFECT: Refer to other documentation. 
•  RECOVERY: Refer to other documentation. 
zstn-evt-application-loop  value is 1018 
"<1> STN Application <2> is looping on window <3>" 
<2> name of application 
<3> STN window name 
•  CAUSE: An application has repeatedly attempted to perform output to a terminated session. (See STNCOM 
command REPLY_MAX_DELAY). The application process name and STN window name are displayed. This 
message is displayed once per session. 
•  EFFECT: None. 
•  RECOVERY: Review the application for proper error handling. 
zstn-evt-auditcoll-start value is 1020 
"<1> AUDITCOLL started to collector <2> version <3>" 
<2> name of AUDITCOLL collector 
<3> STN version and release date 
•  CAUSE: STNCOM command AUDITCOLL was used to open an EMS collector. This event is written to the 
specified collector, not to the standard $0 EMS event collector. 
•  EFFECT: Audit-type events will be written to the specified collector. 
•  RECOVERY: None; informational only. 
zstn-evt-auditcoll-stop  value is 1021 
286 • STN Reference  HP NonStop SSH Reference Manual 