SSH Reference Manual
zstn-evt-gwn-disabled   value is 1062 
"<1> GWN File disabled - using <2> session/window names" 
<2> - Number of session/window names 
•  CAUSE: STN encountered an error with GWN processing as detailed in a previous event. This event also 
occurs once at STN startup, when no PARAM GWN^FILE is present. 
•  EFFECT: Future window names for this STN process use the traditional #ZWNnnnn scheme. If this error 
occurs for multiple STN processes, then duplicate #ZWN names can occur. 
•  RECOVERY: Correct the underlying error and restart the STN process. 
zstn-evt-gwn-allocated  value is 1063 
"<1> GWN File <2> Allocated names <3> to <4>" 
<2> - GWN file name 
<3> - first window name allocated to this STN process 
<4> - last window name allocated 
•  CAUSE: This STN process allocated (reserved) a block of window names from the GWN file. 
•  EFFECT: The specified window names will be used for future sessions for this STN process 
•  RECOVERY: None; informational. 
zstn-evt-abend value is 1 
"<1> Process abend due to <2>" 
<2> provides a brief textual description 
•  CAUSE: An unrecoverable internal error was detected. 
•  EFFECT: The STN process will abend and usually create a ZZSA dump file. If a backup process is running, it 
will take over; if not, STN will terminate. 
•  RECOVERY: If STN is not running with a backup process, STN must be restarted. Forward the ZZSA file to 
Support. 
zstn-evt-alloc   value is 2 
"<1> Allocatesegment err <2> POOL^SIZE <3> words" 
<2> error code 
<3> requested size in words 
•  CAUSE: An extended segment could not be allocated for the STN internal buffer pool. 
•  EFFECT: The STN process will abend and usually create a ZZSA dump file. STN will terminate and will not 
perform a backup takeover. 
•  RECOVERY: If PARAM POOL^SIZE is too large, and the disk volume containing the STN object file is full 
or fragmented, try freeing up some disk space, or carefully reduce the PARAM POOL^SIZE, then restart STN. 
If the problem persists, contact Support. 
HP NonStop SSH Reference Manual  STN Reference • 291 