SSH Reference Manual
zstn-evt-exit-debug value is 25 
"<1> Process exiting debug" 
•  CAUSE: An inspect session from a previous DEBUG command finished.  
•  EFFECT: STN operation continues. Active sessions may timeout if the time spent in inspect mode was too 
long.  
•  RECOVERY: None; informational only. 
Client Messages at the Remote Workstation 
When a TN6530 client (terminal emulator) such as Win6530 or J6530 first connects to STN, several messages are 
displayed as the session is initiated. Each message begins with the letters "STN" followed by a two-digit message 
number for ease of identification. 
STN00 Connected to STN version <version> <date/time> <window-name> 
This is the first message displayed which confirms connection to STN (as distinct from Telserv or other Telnet servers). 
The STN version string is included. <window-name> is in the form \node.$process.#window. 
STN01 Host IP <h> <subnet> Port <p> <window-name> 
This is the second message, which confirms the NSK host IP address <h>, the TCP process name <subnet>, port number 
<p> and finally the full filename of the STN window in the form \node.$process.#window. This information can be 
useful for support purposes. 
STN02 Services: 
This message precedes the list of services displayed. 
STN03 Terminal type <ttype> is not supported 
The TN6530 client (terminal emulator) sent a terminal type identifier unknown to STN. Verify that the terminal emulator 
is properly set for TN6530 emulation. 
STN04 Connected to Dedicated Window <window> 
This message indicates that the session has been automatically connected to a dedicated window named <window> 
whose IP address matches the remote workstation. 
STN05 Dedicated Window(s) are configured for this workstation IP address, but are already in use or 
otherwise unavailable. Session terminated. 
Self-explanatory. 
STN06 
Reserved for future use. 