SST Agent Installation Guide, Version 1.2
Table Of Contents
- HP NonStop SST Agent Installation Guide
- Preface
- Chapter 1: Installing HP NonStop SST Agent
- Appendix A: Installation Information
- Appendix B: Sample INSTINFO File
- Document Feedback Form
Appendix B 14
== Operations Bridge Parameters
If you use AO or OVNM, specify the EMS collector process that is used
by that application here. You should use EDIT again and change
all references of &MC to the correct collector process name.
sst_monitor_collector: &MC
The following is the EMS collector that is used by Base24. Please
change all &B24 to the correct EMS collector process name.
sst_base24_collector: &B24
Please add $VOL.SUBVOL where customer want to create files OB Database Files.
If left empty Files will be created at &inst-subOB.
SST_STATD_FILE:
SST_ATPROF_FILE:
SST_FIPROF_FILE:
SST_MASTDB_FILE:
If param SST_KEEPALIVEINT is 0 (Seconds) then DBREADER($xxDBR) will not send
Keep Alive
Message to Front End. It is recemmended that parameter should have value
greator than 0.
SST_KEEPALIVEINT: 600
This will be the TCPIP process name used by the OB application.
SST_TCPIP_process_name: $ZTC1
SST_AUTOREBUILD_flag is used to specify if Auto rebuild is required each time
ATM is added,
deleted or any changes occur in Static Details of an ATM.
SST_AUTOREBUILD_flag: OFF
SST_REBUILD_CPUS: 0,1
SST_REBUILD_PRI: 160
SST_SBB_flag: OFF
SST_MGR_cpus: 0,1,2,4
SST_MGR_autorestart: 10
SST_LOG_flag: ON
SST_LOG_level: ERROR
SST_LOG_file: &inst-subOB.AOBLOG
SST_LOG_size: 500000