Errors
Subsystem Control Point (SCP) Management Programming Manual520619-001
A-8
–993 ZCOM-ERR-NO-TLE
–993 ZCOM-ERR-NO-TLE
A command message containing ZCOM-TKN-CMD-TIMEOUT could not be processed
because no time-list element (TLE) is available.
Cause. A TLE is used to measure when a specified interval of time has expired. The
command modifier ZCOM-TKN-CMD-TIMEOUT specifies that if a command message
has not completed within a certain time interval, it should be canceled. If no TLE is
available, the interval of time cannot be measured. The command message can be
processed if a TLE becomes available. This is an operating system resource problem.
Effect. The SCP process cannot process the command message and rejects it.
Recovery. Reissue the command. If this error begins to occur frequently, notify the
system manager.
–994 ZCOM-ERR-BAD-TIMEOUT
A command message containing the command modifier ZCOM-TKN-CMD-TIMEOUT
could not be processed because the Guardian SIGNALTIMEOUT procedure call failed.
Cause. The SIGNALTIMEOUT procedure could not be executed. This is an operating
system problem.
Effect. The command is not processed.
Recovery. If this error recurs, contact your Compaq representative.
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
No TLE was available for command timeout
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
SIGNALTIMEOUT ERROR: could not set command timeout