Subsystem Control Point (SCP) Management Programming Manual

Errors
Subsystem Control Point (SCP) Management Programming Manual520619-001
A-19
–810 ZTRC-ERR-LCB-INV
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this
error and is set to 0.
Cause. A specified trace parameter value is out of range or had the wrong format.
Effect. The request is rejected.
Recovery. Correct the value and reissue the request.
–810 ZTRC-ERR-LCB-INV
Tracing of the SCP process was interrupted by a processing error involving an invalid
link control block (LCB).
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this
error and is set to 0.
Cause. The format of the LCB was invalid. This might be an operating system or
internal SCP problem.
Effect. The command is not completed.
Recovery. Retry the command message. If this error recurs, notify your Compaq
representative.
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Internal Error: SCP trace error: invalid LCB format
[; Detail = <1>]