Subsystem Control Point (SCP) Management Programming Manual
Errors
Subsystem Control Point (SCP) Management Programming Manual—520619-001
A-21
–819 ZTRC-ERR-SEG-OVERFLOW
Recovery. Verify that the command is being sent to the correct SCP process and that
the process is actively tracing.
–819 ZTRC-ERR-SEG-OVERFLOW
The trace collector encountered a MOVEX procedure error when working with an
extended data segment.
ZTRC-TKN-INIT-ERR-DETAIL
contains the error number returned by the MOVEX procedure.
Cause. A problem was detected by the MOVEX procedure.
Effect. Trace data is lost.
Recovery. This is an internal problem. Notify your Compaq representative.
–822 ZTRC-ERR-IN-PROGRESS
A trace was in progress when another request to initiate a TRACE was received.
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this
error and is set to 0.
Cause. An SCP process received a request to initiate a trace on a subsystem for which
the SCP process has already activated a trace.
Effect. The request is rejected.
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME <1> token-type ZSPI-TYP-STRING
ZTRC-TKN-INIT-ERR-DETAIL <2> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
TRACE segment overflow; trace data lost for <1>
[; Detail = <2>]
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME <1> token-type ZSPI-TYP-STRING
ZTRC-TKN-INIT-ERR-DETAIL <2> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Trace is currently active for <1> [; Detail = <2>]