Subsystem Control Point (SCP) Management Programming Manual
Errors
Subsystem Control Point (SCP) Management Programming Manual—520619-001
A-24
–836 ZTRC-ERR-SEG-LOCK
Effect. Trace data might be lost.
Recovery. Contact your Compaq representative.
–836 ZTRC-ERR-SEG-LOCK
The extended data segment allocated for trace processing could not be locked.
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this 
error and is set to 0.
Cause. This is an operating system problem.
Effect. Trace data is lost.
Recovery. Contact your Compaq representative.
–840 ZTRC-ERR-DEVNAME-INV
The name specified in the MANAGER, XMGR, or OBJNAME token in the TRACE 
command was invalid.
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this 
error and is set to 0.
Cause. The device name specified in the MANAGER, XMGR, or OBJNAME token was too 
long or had the wrong format.
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Unable to lock the trace segment [; Detail = <1>]
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME <1> token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL <2> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Invalid trace device name for <1> [; Detail = <2>]