Subsystem Control Point (SCP) Management Programming Manual
Errors
Subsystem Control Point (SCP) Management Programming Manual—520619-001
A-26
–846 ZTRC-ERR-SCP-INTL-ERR
–846 ZTRC-ERR-SCP-INTL-ERR
An SCP process trace-processing error occurred.
Cause. The SCP process detected an error during tracing activity (a call to 
DSM_TRACE_INIT_ specified the wrong CPU).
Effect. The trace is canceled.
Recovery. Restart the SCP process and reissue the request. If the error recurs, contact 
your Compaq representative.
–847 ZTRC-ERR-DEVICEINFO-INV
The SCP process that is executing a TRACE command called the Guardian 
DEVICEINFO procedure, but the procedure returned an invalid response.
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this 
error and is set to 0.
Cause. The trace target process responded improperly to a DEVICEINFO call.
Effect. The trace is canceled.
Recovery. Restart the target process and reissue the request. If the error recurs, contact 
your Compaq representative.
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Internal Error: SCP trace error encountered
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME <1> token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL <2> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Trace target process <1> responded improperly to deviceinfo
[; Detail = <2>]