Subsystem Control Point (SCP) Management Programming Manual
Errors
Subsystem Control Point (SCP) Management Programming Manual—520619-001
A-27
–848 ZTRC-ERR-COLL-INTL-ERR
–848 ZTRC-ERR-COLL-INTL-ERR
A collector process encountered a file-system error.
Cause. The trace-data collector process initiated by an SCP process attempted to
execute a file-system procedure call, and the procedure returned an error.
Effect. The trace is stopped.
Recovery. Stop the current trace and start a new trace. If the error recurs, contact your
Compaq representative.
–849 ZTRC-ERR-START-PEND
The server process specified in a trace initiation command has not yet completed a
previous trace initiation command.
Cause. The SCP process is awaiting notification from the server that an outstanding
trace has been successfully initiated. Until the server returns this notification, the SCP
process cannot forward a new trace command to that server.
Effect. The trace command is rejected.
Recovery. Wait a few seconds and reissue the request.
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Internal Error: Trace collector error
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
TRACE START is pending; retry trace operation