Subsystem Control Point (SCP) Management Programming Manual
Errors
Subsystem Control Point (SCP) Management Programming Manual—520619-001
A-30
–854 ZTRC-ERR-TRACE-FILE-ERR
Cause. The SCP process issues a call to the DSM_TRACE_INIT_ procedure based on
the information provided by the requester in the TRACE-MODIF structure in the
TRACE command. Either some value or values provided by the requester are invalid, or
an internal error resulted in SCP making a faulty procedure call.
Effect. The requested trace is not initiated.
Recovery. Use the preceding table to identify the invalid value, correct that value as
specified in the TRACE-MODIF structure, and reissue the request.
–854 ZTRC-ERR-TRACE-FILE-ERR
A collector process detected a file-system error on a trace file.
ZTRC-TKN-INIT-ERR-DETAIL
contains the file-system error.
Cause. The collector process encountered a file-system error while trying to create,
open, or write to the trace file.
Effect. The effect depends on the specific error but might involve trace cancellation and
loss of trace data.
Recovery. Resolve the error condition indicated by the specified file-system error
(contained in ZTRC-TKN-INIT-ERR-DETAIL).
20 “BACKUP” Not checked
21 “COUNT” Number of trace records to record is less than 0
or too large
22 “RECSIZE” Specified record size is less than 16 or greater
than the specified block size
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Trace file error: File System error: <1>
Error
Number
Parameter Name Text
Inserted in SCF Message Problem