–854 ZTRC-ERR-TRACE-FILE-ERR
Cause. The SCP process issues a call to the DSM_TRACE_INIT_ procedure based on 
the information provided by the requester in the TRACE-MODIF structure in the 
TRACE command. Either some value or values provided by the requester are invalid, or 
an internal error resulted in SCP making a faulty procedure call.
Effect. The requested trace is not initiated.
Recovery. Use the preceding table to identify the invalid value, correct that value as 
specified in the TRACE-MODIF structure, and reissue the request.
–854 ZTRC-ERR-TRACE-FILE-ERR
A collector process detected a file-system error on a trace file.
ZTRC-TKN-INIT-ERR-DETAIL
contains the file-system error.
Cause. The collector process encountered a file-system error while trying to create, 
open, or write to the trace file.
Effect. The effect depends on the specific error but might involve trace cancellation and 
loss of trace data.
Recovery. Resolve the error condition indicated by the specified file-system error 
(contained in ZTRC-TKN-INIT-ERR-DETAIL).
20 “BACKUP” Not checked
21 “COUNT” Number of trace records to record is less than 0 
or too large
22 “RECSIZE” Specified record size is less than 16 or greater 
than the specified block size
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Trace file error: File System error: <1>
Error 
Number
Parameter Name Text 
Inserted in SCF Message Problem