–857 ZTRC-ERR-COLL-OPEN-ERR
–857 ZTRC-ERR-COLL-OPEN-ERR
The SCP process could not open a collector process.
ZTRC-TKN-INIT-ERR-DETAIL
contains the file-system error.
Cause. The SCP process encountered a file-system error while trying to open the 
collector process.
Effect. No trace is initiated.
Recovery. Resolve the error condition by referring to the specific file-system error code 
returned in ZTRC-TKN-INIT-ERR-DETAIL.
–858 ZTRC-ERR-MOM-DIED
The process that created the collector no longer exists.
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this 
error and is set to 0.
Cause. The process that created the collector—usually an SCP process—is no longer 
running, or the CPU in which the creator process was running failed.
Effect. The collector issues this event and then stops.
Recovery. Restart an SCP process and retry the trace.
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
File error while opening the collector; File System error: 
<1>
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
TRACE collector MOM died[; Detail = <1>]