Subsystem Control Point (SCP) Management Programming Manual

Errors
Subsystem Control Point (SCP) Management Programming Manual520619-001
A-32
–857 ZTRC-ERR-COLL-OPEN-ERR
–857 ZTRC-ERR-COLL-OPEN-ERR
The SCP process could not open a collector process.
ZTRC-TKN-INIT-ERR-DETAIL
contains the file-system error.
Cause. The SCP process encountered a file-system error while trying to open the
collector process.
Effect. No trace is initiated.
Recovery. Resolve the error condition by referring to the specific file-system error code
returned in ZTRC-TKN-INIT-ERR-DETAIL.
–858 ZTRC-ERR-MOM-DIED
The process that created the collector no longer exists.
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this
error and is set to 0.
Cause. The process that created the collector—usually an SCP process—is no longer
running, or the CPU in which the creator process was running failed.
Effect. The collector issues this event and then stops.
Recovery. Restart an SCP process and retry the trace.
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
File error while opening the collector; File System error:
<1>
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
TRACE collector MOM died[; Detail = <1>]