Subsystem Control Point (SCP) Management Programming Manual
Errors
Subsystem Control Point (SCP) Management Programming Manual—520619-001
A-34
–861 ZTRC-ERR-TRC-RCV-FILE-ERR
Recovery. Retry the request. If the problem recurs, contact your Compaq 
representative.
–861 ZTRC-ERR-TRC-RCV-FILE-ERR
The SCP process detected an error trying to write to or read from its $RECEIVE file.
ZTRC-TKN-INIT-ERR-DETAIL
contains the file-system error if available.
Cause. The SCP process (or the process that called DSM_TRACE_INIT_) encountered 
a file system error while trying to write to or read from its receive file.
Effect. No trace is initiated.
Recovery. Retry the request. If the problem recurs, contact your Compaq 
representative.
–862 ZTRC-ERR-TRACE-FILE-SIZE
The trace file cannot contain the amount of data specified by the PAGES parameter.
ZTRC-TKN-INIT-ERR-DETAIL
is included in the error list generated by an SCP process. It is not applicable to this 
error and is set to 0.
Cause. The trace file is not large enough to contain the amount of data requested by the 
PAGES parameter.
Effect. The trace is not initiated.
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL <1> token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
TRACE PROCEDURE’s $RECEIVE file error; File System error: <1>
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM
 ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING
 ZTRC-TKN-INIT-ERR-DETAIL token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding SCF Error Message
Existing TRACE FILE is not big enough for PAGES specified.