SWAN 2 Concentrator Installation and Support Guide

Replacing a LAN Logic Board (LB)
SWAN 2 Concentrator Installation and Support Guide429593-010
8-2
Replace the LAN LB
1. In the tree pane of the Management window, select the SWAN 2 concentrator
containing the LAN LB to be replaced.
2. Click the Attributes tab in the details pane to determine the Track ID of that
SWAN 2 concentrator.
3. Physically locate the SWAN 2 concentrator that has this Track ID on the back
panel of its chassis (see Figure 1-4 on page 1-5).
4. LAN LBs are located on the front panel of the SWAN 2 concentrator, and each
LAN LB is labeled (see Figure 1-1 on page 1-3).
Replace the LAN LB
Review Standard Operating Practices
Refer to Standard Operating Practices on page 5-3.
Remove the LAN LB
1. Put on an ESD wriststrap and connect the grounding clip securely to an unpainted
metal surface on the SWAN 2 concentrator containing the LAN LB to be replaced.
Table 8-2. Replacement Checklist for a LAN LB
Step Description
1.
Review Standard Operating Practices.
2.
Remove the LAN LB.
3.
Unpack and Inspect the Replacement LAN LB.
4.
Install the Replacement LAN LB.
5.
Verify the Installation of the Replacement LAN LB.
Note. Whenever you handle a LAN LB, follow standard operating practices to avoid damage to
the equipment.