SWAN 2 Concentrator Installation and Support Guide
Replacing a LAN Backplane Interface Card (BIC)
SWAN 2 Concentrator Installation and Support Guide—429593-010
9-3
Remove the LAN BIC
Remove the LAN BIC
1. Put on an ESD wriststrap and connect the grounding clip securely to an unpainted
metal surface on the SWAN 2 concentrator rack containing the LAN BIC to be
replaced.
2. Disconnect the RJ-45 plug of the Ethernet cable from the RJ-45 jack of the
LAN BIC to be replaced.
3. Loosen the thumbscrew on the LAN BIC to be replaced and pull the LAN BIC
partway out until it is unseated from the SWAN 2 concentrator chassis.
4. Grasp the LAN BIC in one hand and, while supporting the bottom edge of the
LAN BIC with the other hand, slowly pull the LAN BIC all the way out of the slot.
5. Place the LAN BIC in an ESD protective bag and pack it into its original shipping
container.