SWAN 2 Concentrator Installation and Support Guide
Replacing a LAN Backplane Interface Card (BIC)
SWAN 2 Concentrator Installation and Support Guide—429593-010
9-6
Verify the Installation of the Replacement LAN BIC
Verify the Installation of the Replacement LAN BIC
1. Make sure that the RJ-45 connector is connected to the LAN BIC.
2. Make sure that the LAN BIC status LEDs are functioning correctly.
•
Figure 2-7 on page 2-34 shows the LAN BIC LED indicators in detail.
•
Table 2-4 on page 2-31 describes the functions of these LEDs.
•
Table 2-5 on page 2-37 describes corrective actions for abnormal LED states.
3. If the LAN BIC status LEDs are not functioning correctly:
•
Reseat the LAN BIC.
•
Check the LAN BIC for damage. Replace the LAN BIC if it is damaged.
•
Use the OSM Service Connection or TSM Service Application to check for
alarms related to the LAN BIC’s associated LAN LB.