SWAN 2 Concentrator Installation and Support Guide

Replacing a Power Supply
SWAN 2 Concentrator Installation and Support Guide429593-010
10-6
Verify the Installation of the Replacement Power
Supply
Verify the Installation of the Replacement Power Supply
Verify the installation of the replacement power supply by examining the power
supply’s status LEDs. Figure 2-5 on page 2-33 shows the locations of the power supply
LEDs, and Table 2-4 on page 2-31 describes the functions of these LEDs.
Make sure that the green power-on LED is lit.
If the power-on LED is not lit:
°
Reseat the power supply.
°
Check the power supply for damage. Replace the power supply if it is
damaged.
°
Use the TSM Service Application to check for alarms related to the power
supply.
If after attempting these methods the power-on LED is not lit, replace the power
supply.
If the amber fault LED is lit, see Table 2-5 on page 2-37.