SWAN 2 Concentrator Installation and Support Guide
Replacing a Chassis
SWAN 2 Concentrator Installation and Support Guide—429593-010
13-4
Stop and Reconfigure the Associated SWAN 2
Concentrator
Stop and Reconfigure the Associated SWAN 2 Concentrator
1. Use the SCF STOP ADAPTER command with the SUB ALL option to stop the
concentrator and its subordinate objects (see Example 13-2).
2. Reconfigure the WAN subsystem software with the configuration track-ID of the
replacement SWAN 2 concentrator containing the replacement chassis using the
SCF ALTER ADAPTER. Example 13-3 shows how to alter the configuration
track-ID on the SWAN 2 concentrator named $ZZWAN.#S01. For more
information about this command, see the WAN Subsystem Configuration and
Management Manual.
3. Power off the SWAN 2 concentrator containing the chassis to be replaced by
unplugging both AC power cords from the AC power receptacles on the SWAN 2
concentrator.
Label the Communication Cables Connected to the Associated
SWAN 2 Concentrator
1. Label each interface converter cable connected to the SWAN 2 concentrator
containing the chassis you are replacing to indicate which WAN BIC and WAN port
it is connected to. Each WAN BIC is labeled with an identifier (see Figure 7-1 on
page 7-3).
2. Label each Ethernet cable connected to the associated SWAN 2 concentrator to
indicate which Ethernet port it is connected to.
You will use this information when connecting these cables to the SWAN 2
concentrator containing the replacement chassis.
Example 13-2. Sample SCF STOP ADAPTER Command
STOP ADAPTER $ZZWAN.#S01, SUB ALL
Example 13-3. Sample SCF ALTER ADAPTER Command to Alter Track-ID
ALTER ADAPTER $ZZWAN.#S01, TRACKID "new_track_id"
Note. The battery provides 30 seconds of backup DC power if you unplug the AC power cords.