SWAN 2 Concentrator Installation and Support Guide
Using TSM to Update SWAN 2 CLIP Firmware
SWAN 2 Concentrator Installation and Support Guide—429593-010
B-8
Step 2: Check Location and Version of the New
SWAN 2 CLIP Firmware
Step 2: Check Location and Version of the New SWAN 2 CLIP
Firmware
To determine the location and version of the new SWAN 2 CLIP firmware object file for
the RVU or SPR, use the VPROC command. At a TACL prompt, enter the VPROC
command:
VPROC $SYSTEM.CSSnn.C7953Q00
where nn is the number of the $SYSTEM.SYSnn.
Step 3: Check Current Firmware Version in the SWAN 2 CLIPs
Determine the firmware version currently running in each SWAN 2 CLIP using either
the TSM Service Application to show the attributes of each CLIP or by using the SCF
STATUS SERVER $ZZWAN.#conc-name.clip-num, DETAIL command.
Step 4: Stop the SWAN 2 Concentrator and CLIPs
Stop the SWAN 2 concentator and terminate operation of all CLIPs.
•
If you are using SCF, enter the Stop Adapter command with the SUB ALL option to
stop the concentrator and CLIPs:
SCF STOP ADAPTER $ZZWAN.#S01, SUB ALL
•
Or if you are using the TSM Service Application, use the Actions dialog box. For
example: