SWAN 2 Concentrator Installation and Support Guide
Replacing a SWAN 2 Concentrator
SWAN 2 Concentrator Installation and Support Guide—429593-010
3-6
Install the Replacement SWAN 2 Concentrator
SWAN Concentrator Configuration Planning Form provided in the WAN Subsystem
Configuration and Management Manual.
Install the Replacement SWAN 2 Concentrator
1. Rack-mount the replacement SWAN 2 concentrator following the procedure
described in Rack-Mount the SWAN 2 Concentrator on page 2-9.
2. Connect the Ethernet cables to the replacement SWAN 2 concentrator following
the procedure described in Connect the Ethernet Cables on page 2-11 and
referring to the labels you put on the cables.
3. Connect the interface converter cables to the WAN ports on the replacement
SWAN 2 concentrator following the procedure described in Connect the Interface
Converter Cables to the WAN Ports on page 2-29 and referring to the labels you
put on the cables.
4. Power-on the replacement SWAN 2 concentrator following the procedure
described in Power On the SWAN 2 Concentrator and Run the Power-On Self-Test
(POST) on page 2-31.
Resume Operations on the SWAN 2
Concentrator
1. Start the replacement SWAN 2 concentrator. Example 3-4 shows how to start the
SWAN 2 concentrator named $ZZWAN.#S01 using the SCF START ADAPTER
command.
The ALLOW ALL ERRORS option instructs SCF to start the concentrator even if
there are errors. For example, if one of the six CLIPs does not start, SCF attempts
to start the remaining five CLIPs. The SUB ALL option starts the concentrator and
its subordinate objects.
2. Create the data communications subsystem objects if they are not already running.
Example 3-5 shows how to start a DEVICE object, which creates the
corresponding data communications subsystem object.
Example 3-4. Sample SCF START ADAPTER Command
ALLOW ALL ERRORS
START ADAPTER $ZZWAN.#S01, SUB ALL
Example 3-5. Sample SCF START DEVICE Command
START DEVICE $ZZWAN.#X25l1