SWAN 2 Concentrator Installation and Support Guide

SWAN 2 Concentrator Installation and Support Guide429593-010
5-1
5
Servicing SWAN 2 Concentrator
Components
Replacing SWAN 2 Concentrator Components
This guide provides detailed replacement procedures for all SWAN 2 concentrator
components. For a description of these components, see SWAN 2 Concentrator
Components on page 1-2.
Component Service Classes
Replacing SWAN 2 Concentrator Components Page 5-1
Component-Replacement Tools Page 5-2
Standard Operating Practices Page 5-3
ESD Guidelines Page 5-4
Table 5-1. Component Service Classes
Component Service Class SWAN 2 Component Training Required
Class-1: A communications
subsystem problem probably won’t
occur if you follow the documented
replacement procedure correctly.
CLIPs
WAN BICs
No previous experience
with replacing components
required.
Class-2: A communications
subsystem outage might occur if
you do not follow the documented
replacement procedure correctly.
Battery
LAN LBs
LAN BICs
Power supplies
Chassis with
midplane
You should have three or
more months’ experience
replacing components or
equivalent training.
Class-3: A communications
subsystem outage or damage to the
equipment is likely to occur if you do
not follow the documented
replacement procedure correctly.
Fans You should have six or
more months’ experience
replacing components or
equivalent training.