SWAN Concentrator and WAN Subsystem Troubleshooting Guide
Error and Informational Messages With Recovery
Actions
SWAN Concentrator and WAN Subsystem Troubleshooting Guide—426992-008
7-5
BOOTP Error Messages
2. If you have determined that it is not a configuration problem, check if you have
WANBoot version T7909AAH or T7909AAI.
3. If you have WANBoot SPR T7909AAH or AAI installed, upgrade to SPR T7909AAJ
or above. (Check the appropriate requisite WANMgr and ConMgr for the WANBoot
SPR being installed.)
4. If the problem still persists, stop the corresponding WANBoot process and start the
process again.
5. If Step 4 has solved the problem and the BOOTP requests are not being repeated,
it is likely that more SWANs are configured for this WANBoot process.
6. If the problem still exists, contact your HP service provider.
Versions: Applicable with T7953AAH and G06.07 only.
1502
BOOTP request from unknown SWAN.
Message
Recovery
Indicates that the SWAN with TRACKID XR4T77 CLIP 2 is requesting for BOOTP, but
the SWAN is not configured in this system. It is possible that the TRACKID has been
configured incorrectly.
Check and add/correct the configuration of ADAPTER.
Version: G06.07 and T7953AAH SWAN firmware.
1505
BOOTP request successful.
Message
WANBoot:
BOOTP received for ?? TRACKID XR4T77,
CLIP 2, IP Address ?.?.?.?, Path B
WARNING: BOOTP received from unknown SWAN; not REPLIED
WANBoot:
BOOTP request successful for SWAN00,
TRACKID X017R3, CLIP 3, IP Address
192.168.10.192, PATH A