SWAN Concentrator and WAN Subsystem Troubleshooting Guide

Error and Informational Messages With Recovery
Actions
SWAN Concentrator and WAN Subsystem Troubleshooting Guide426992-008
7-14
Error Messages
Recovery
The program file associated with the DEVICE (or the DIAG Task file name in case of
Task actions) is not present or ConMgr cannot read it. Correct the file problem, then
retry starting the LINE.
501
Ownership error.
Message
Recovery
The ConMgr found that the Request for Activate PATH should be tried from the other
CPU to achieve optimum performance. No user recovery action is needed. The
DEVICE will retry on the other CPU.
501
TASK stopped.
Message
Recovery
None. The task associated with the LINE is STOPPED. Start the task by using the SCF
START TASK command. The task to start would be DLC0 for LINE 0 and DLC1 for
LINE 1. Retry starting the LINE after starting the task.
ConMgr:
Activate PATH for $BSC, LDEV 139
Status : FAILED
Path A : Ownership
Path B : No Response from CLIP
Recovery : Retry after CPU switch
ConMgr:
Activate PATH for $BSC, LDEV 139
Status : FAILED
Component: Configuration
Reason : TASK Stopped