SWAN Concentrator and WAN Subsystem Troubleshooting Guide
Error and Informational Messages With Recovery 
Actions
SWAN Concentrator and WAN Subsystem Troubleshooting Guide—426992-008
7-16
Error Messages
501
Version incompatible.
Message
Recovery
The versions of ConMgr and WANMgr are not compatible. Check the requisite in the 
softdoc, then install the correct versions.
505
 TCPIP process down.
Message 
Recovery
The TCP/IP process associated with PATH A is down. Start the associated TCP/IP 
process, then retry the action.
 ConMgr: 
 Activate PATH for $BSC, LDEV 139 
 Status : FAILED 
 Component: WANMgr
 Reason : Version Incompatible
 Recovery : None
  ConMgr: Add Task for Trackid
 X017R3, Adap
 SWAN00.2
 Status : FAILED
 Path A : TCPIP Process Down
 Error: 14
 Path B : Path Not Configured
 Recovery : Retry after a long delay