SWAN Concentrator and WAN Subsystem Troubleshooting Guide

Verifying the SWAN Configuration
SWAN Concentrator and WAN Subsystem Troubleshooting Guide426992-008
2-14
HP Manufacturing Naming Conventions (G06.26 and
Earlier RVUs)
portid
is the combination of the slot number and port number mapped in this way:
slot
is the actual physical slot number in the enclosure:
m
is an alphabetic value (A-Z) assigned automatically by the WAN manager process.
n
is an alphanumeric value (A-Z or 0-9) assigned automatically by the WAN manager
process.
concnum
is the incremental number of the SWAN concentrator. For example, the first SWAN
concentrator would be 01, the second SWAN concentrator would be 02, and so on.
Slot
Number
Port
Number portid
Slot
Number
Port
Number portid
51005308
51115319
5122532A
5133533B
5204540C
5215541D
5226542E
5237543F
Number Description
51 to 54 A LAN adapter
Note. The WAN manager process does not impose any restrictions on adding a
PROCESS using the convention name, but when you add WAN processes, use these
names to distinguish between the generated process names and the user-supplied
process names.