SWAN Concentrator and WAN Subsystem Troubleshooting Guide
Verifying the SWAN Configuration
SWAN Concentrator and WAN Subsystem Troubleshooting Guide—426992-008
2-16
G4SA Naming Conventions (G06.24, G06.25, and
G06.26 RVUs)
cabid
is the two-digit group number that identifies the processor enclosure that is
connected to the IOAM or to the IOAM enclosure that contains the G4SA; cabid is
also the group number.
module
identifies whether the G4SA is installed in module 2 or 3 of an IOAM. A module is
either 2 or 3.
slot
is the G4SA’s physical slot number in the IOAM:
processorid
specifies the processor in which the LANMON process is running. For example,
#ZLM01 specifies the LANMON in processor 1.
IOAM position 1-5 + Module
is the IOAM group's position in the topology where one of the IOAMs is connected
to a processor enclosure; this convention uses alphabetical letters A through J:
In the above table, A is Module 2 of the IOAM connected to the first port of the
processor enclosure's ServerNet Expansion Board (SEB).
group Description Range of Values
0n The object is in processor enclosure n.01-08
1n The object is in I/O enclosure n. The IO
enclosure can be physically attached to
as many as four processors in the inner
tetrahedron, but the processor
enclosure number is always 1.
11,12,13,14,15
Number Description
1 to 5 For the G4SA.
The supported G4SA installation slots differ by system type. To determine the supported installation
slots for your G4SA, see the planning guide for your system (for example, the Integrity NonStop
S-Series Planning Guide)
ABCDEFGH I J
1, 2 1, 3 2, 2 2, 3 3, 2 3, 3 4, 2 4,3 5, 2 5, 3