Verifying the WAN Subsystem
SWAN Concentrator and WAN Subsystem Troubleshooting Guide426992-008
3-5
Starting the WAN Subsystem Processes and Objects
c. If the routes on the preferred and alternate TCP/IP processes are not started,
use the SCF START ROUTE command to start them:
START ROUTE $pref-tcpip-process.#route-name
START ROUTE $alt-tcpip-process.#route-name
5. Start the SNMP agent processes that support the SNMP trap multiplexer
processes by using the SCF START PROCESS command:
START PROCESS $snmp-agent-process
6. Start a WAN subsystem ConMgr process by using the SCF START PROCESS
command:
START PROCESS $ZZWAN.#process-name
7. Start the SWAN concentrator by using the SCF START ADAPTER command with
the SUB ALL option:
START ADAPTER $ZZWAN.#adapter-name, SUB ALL
8. Start a WAN subsystem device (DEVICE object) by using the SCF START DEVICE
command:
START DEVICE $ZZWAN.#device-name
9. Verify that each process and object is in the STARTED state by using the SCF
STATUS command as described in Verifying the WAN Subsystem Processes and
Objects on page 3-1.
Note. The SNMP, TFTP, and WANBoot processes are automatically configured starting with