SWAN Concentrator and WAN Subsystem Troubleshooting Guide

Verifying the SWAN Hardware
SWAN Concentrator and WAN Subsystem Troubleshooting Guide426992-008
4-10
SWAN Concentrator Cabling
CLIP replacement procedure, see the SWAN 2 Concentrator Installation and Support
Guide).
Error ID 4002032
This error is returned if the OSM Service Connection or TSM Service Application could
not obtain power-on self-test (POST) results because the selected CLIP could not be
accessed. For a SWAN concentrator (T3880) there is no recovery for this error; you
must replace the SWAN concentrator. For a SWAN 2 concentrator (T3881), you must
replace the CLIP (For information about the CLIP replacement procedure, see the
SWAN 2 Concentrator Installation and Support Guide).
SWAN Concentrator Cabling
The front panel of the ServerNet wide area network (SWAN) concentrator contains two
RJ-45, 10 Base-T twisted-pair Ethernet ports, which connect the SWAN concentrator
to the Integrity NonStop NS-series or NonStop S-series server.
The back panel of the SWAN 2 concentrator contains two RJ-45, 10/100 Base-T
twisted-pair Ethernet ports, which connect the SWAN 2 concentrator to the Integrity
NonStop NS-series or NonStop S-series server.
Ethernet connections to the server can be made:
Directly to Ethernet 4 ServerNet adapters (E4SAs), Fast Ethernet ServerNet
adapters (FESAs), Gigabit Ethernet ServerNet adapters (GESAs), and Gigabit
Ethernet 4-port ServerNet adapters (G4SAs) using a customer-supplied crossover
cable.
Indirectly through customer-supplied, industry-standard Ethernet switches, hubs, or
routers. For more information, see the SWAN Concentrator Installation and
Support Guide or the SWAN 2 Concentrator Installation and Support Guide.
For maximum fault-tolerance, HP recommends that you connect a
SWAN concentrator directly to an E4SA, FESA, GESA, or G4SA rather than
through an Ethernet hub. If you use an Ethernet hub, you must carefully monitor
the state of the hub.