System Generation Manual for G-Series RVUs
SYSGENR Messages
System Generation Manual for G-Series RVUs—523407-001
A-35
SYSGENR Message Descriptions
Cause. The required system process process is not among the supplied process
files. This message appears in the body of the listing, at the point where the error was
detected.
Effect. SYSGENR finishes scanning the CONFTEXT file and then terminates.
Recovery. Supply the missing file, by ordering a new SUT, if necessary.
Cause. The SYSTEM_PROCESS_LIBRARY_FILES entry of the configuration file lists
more than one file.
Effect. SYSGENR finishes scanning the CONFTEXT file and then terminates.
Recovery. Remove all files but the DP2 driver file TODRVR. Then rerun SYSGENR.
Cause. The SYSTEM_PROCESS_LIBRARY_FILES entry lists more than one object
file. This is because BIND combined the object files into a single file, using BIND, but
did not accelerate them.
Effect. SYSGENR continues.
Recovery. To ensure that you have an accelerated version of the system process
library, remove the additional files from the SYSTEM_PROCESS_LIBRARY_FILES
entry. To do this, gather the items listed on page A-1, then call your service provider.
Cause. SYSGENR ran TEMPLI to create the EMS template files, but TEMPLI has not
completed normally.
Effect. SYSGENR finishes scanning the CONFTEXT file and then terminates.
Recovery. Gather the items listed on page A-1, then call your service provider.
SYSTEM PROCESS NOT FOUND: process
SYSTEM PROCESS USER LIBRARY CAN NOT CONTAIN MULTIPLE FILES
SYSTEM PROCESS USER LIBRARY IS NOT ACCELERATED
TEMPLI DID NOT STOP AFTER EXIT COMMAND