Cause. SYSGENR has not found a required interrupt handling procedure in the
system library. The procedure is identified in an accompanying message,
“PROCEDURE name NOT FOUND...”. This is an internal problem.
Effect. SYSGENR terminates.
Recovery. Gather the items listed on page A-1, then call your service provider.
Cause. This version of SYSGENR does not support software RVUs prior to B00.
Effect. SYSGENR terminates.
Recovery. Either run an older version of SYSGENR on a pre-B00 RVU or, after
gathering the items listed on page A-1, contact your service provider.
Cause. You have created a CONFTEXT file for a single processor for a system that
does not support single processors.
Effect. SYSGENR finishes scanning the CONFTEXT file and then terminates.
Recovery. Correct the CONFTEXT file and rerun SYSGENR.
Cause. The STANDARD_MICROCODE paragraph lists a file that does not belong
with the instruction set microcode files.
Effect. SYSGENR terminates.
Recovery. Remove the file that does not belong so that only files containing
instruction set microcode are listed. Then rerun SYSGENR.
Cause. You have configured too many DEFINES entries for the system, which in turn
filled a SYSGENR internal table. This message appears in the body of the listing, at
the point where the error was detected.
Effect. SYSGENR terminates.
Recovery. Reduce the number of DEFINES entries and rerun SYSGENR.
THIS IS A REQUIRED INTERRUPT HANDLING PROCEDURE
THIS SYSGEN MUST RUN ON A B00 OR GREATER RELEASE
THIS SYSTEM TYPE MUST HAVE MULTIPLE CPUS
TOO MANY CPU MICROCODE FILES
TOO MANY DEFINES