TACL Programming Guide
Using EMS
Using Programmatic Interfaces
7–14 107365 Tandem Computers Incorporated
Figure 7-3. Generating an EMS Event (Page 2 of 3)
 == Build the event and initialize the EMS buffer
 [#SET evt_error [#EMSINIT evt_buf [ZEMS^VAL^EXTERNAL^SSID]
 [evt_num] ZEMS^TKN^TEXT [#charcount evt_text]
 [evt_text]]
 ]
 [#IF [evt_error] |THEN|
 #OUTPUT *ERROR* EMSINIT error [evt_error]
 #RETURN
 ]
 == If emphasis is TRUE, set the CRITICAL flag
 [#IF [emphasis] |THEN|
 #SET evt_error [#SSPUT evt_buf ZEMS^TKN^EMPHASIS &
 [ZSPI^VAL^TRUE]]
 [#IF [evt_error] |THEN|
 #OUTPUT *ERROR* SSPUT error [evt_error] on &
 Emphasis token
 #RETURN
 ] == End IF
 ] == End IF
 == If action is TRUE, set the ACTION-NEEDED flag
 [#IF [action] |THEN|
 #SET evt_error [#SSPUT evt_buf ZEMS^TKN^ACTION^NEEDED &
 [ZSPI^VAL^TRUE]]
 [#IF [evt_error] |THEN|
 #OUTPUT *ERROR* SSPUT error [evt_error] on &
 Action-Needed token
 ] == End IF
 == SET the action-ID token to a unique value
 #SET evt_error [#SSPUT evt_buf ZEMS^TKN^ACTION^ID
 [action_id]]
 [#IF [evt_error] |THEN|
 #OUTPUT *ERROR* SSPUT error [evt_error] on Action-ID
 #RETURN
 |ELSE| #SET action_id [#COMPUTE action_id + 1]
 ]
 ]
 == Send the event buffer to the Collector
 #APPENDV req_prompt evt_buf
 #UNFRAME
] == End of build_evt