Tandem Capacity Model (TCM) Manual

61
Too many disk volumes
Cause
The total number of disk volumes defined in the Measure data files exceeds the maximum currently
allowed by MeasTCM.
Effect
The program terminates. No CSV files are produced.
Recovery
Reduce the number of disk volumes by limiting the number of systems under study. If you cannot
reduce the number of disk volumes, contact the GCSC.
62
Too many processes
Cause
The total number of processes in the current system exceeds the maximum currently allowed by
MeasTCM.
Effect
The program terminates. No CSV files are produced.
Recovery
Reduce the number of processes defined by narrowing down the time window (CSVHI-CSVLO)
in the MeasTCM control file. If you cannot reduce the number of entries, contact the GNSC.
63
Measure Discopen record allocation error n times
Cause
1. Entity overflow errors were detected in the Measure files during processing for discopen
records. n specifies the number of discopen entities ignored because of the Measure error.
2. Entity overflow errors were detected in the Measure files during processing for discopen
total records.
Effect
1. MeasTCM ignores the invalid discopen entries. The CSVs files and audit report are created
if requested.
2. The program abends. A process snapshot file is created. CSV files are not created.
Recovery
1. None needed. If the number of invalid entries is too high, take another measurement with
a smaller total time or with fewer intervals and try MeasTCM again.
2. Take another measurement with a smaller total time or with fewer intervals and try MeasTCM
again.
64
Invalid report file name
Cause
The file name following the keyword REPORT in the MeasTCM control file is invalid.
Effect
The program terminates. No CSV files are produced.
Recovery
Edit the MeasTCM control file and correct the report file name. It should correspond to a valid
Spooler collector process name that can be qualified.
65
Spooler collector COBOLASSIGN error n
MeasTCM Termination Messages 203