Tandem Capacity Model (TCM) Manual
Essential CPU data missing. CPU=nn
Cause
The Measure data is incomplete. CPU number nn is missing.
Effect
The program terminates. No CSV files are produced.
Recovery
Rerun Measure. Include all CPUs (CPU*).
87
Entity overflow has occured.
Cause
A MEASURE entity overflow error occurred during the MeasTCM processing.
Effect
MeasTCM ignores the entities affected by the overflow. A count of the number of entities is kept
and given in a separate message. The CSV files and audit report are produced if requested.
Recovery
None. If the number of entities ignored is too large, take another measurement with a smaller
total time or with fewer intervals and try again.
88
Input CONTROL FILE does not exist.
Cause
The MeasTCM control file was not specified on the command line.
Effect
The program terminates. No CSV files are produced.
Recovery
Specify the MeasTCM control file on the command line. For more information, see Chapter 3:
“Using MeasTCM”.
89
NSK-version required as second CONVERTTO parameter.
Cause
In the control file, the second parameter (NonStop Kernel version) was not specified for the
CONVERTTO factor. This NonStop kernel is necessary if the first parameter, the processor type,
does not match that of any of the Measure data files.
Effect
The program terminates. No CSV files are produced.
Recovery
In the control file, add the second parameter for the CONVERTTO factor. This parameter is a
three-lettered entity. The list of allowable values is included in the sample control file CNTLFILE.
90
CONVERTTO NSK-version (Param 2) incompatible for CPU-type (Param 1).
Cause
In the control file, the second parameter of CONVERTTO (NonStop Kernel version) is not
compatible with the first parameter (CPU type). This second parameter is necessary if the first
parameter, the processor type, does not match that of any of the Measure data files.
Effect
The program terminates. No CSV files are produced.
208 MeasTCM Error Messages