Tandem Capacity Model (TCM) Manual

Recovery
In the control file, alter the second parameter for the CONVERTTO factor. This parameter is a
three-lettered entity. The list of allowable values is mentioned in the sample control file CNTLFILE.
91
Invalid DISKPOWER type parameter in control file.
Cause
In the MeasTCM control file, one or more than one of the DISKFACTOR keyword parameters is
incorrect.
Effect
The program terminates. No CSV files are produced.
Recovery
Edit the MeasTCM control file and correct the DISKFACTOR parameter or parameters.
92
Controller not available for DISK type.
Cause
One of the Measure Disk entity records contains a controller of type n, which this version of
MeasTCM does not support.
Effect
The program terminates. A saveabend is created. No CSV files are produced.
Recovery
Check if this controller type is valid and obtain an updated product version of MeasTCM if
necessary.
93
More than one DISKCONVERTTO entry in control file.
Cause
The MeasTCM control file contains more than one DISKCONVERTTO entry.
Effect
The program terminates. No CSV files are produced.
Recovery
Edit the MeasTCM control file and remove the erroneous DISKCONVERTTO entry or entries.
94
Invalid DISKCONVERTTO parameter in control file.
Cause
The first parameter following the DISKCONVERTTO keyword in the MeasTCM control file does
not represent a valid disk type.
Effect
The program terminates. No CSV files are produced.
Recovery
Edit the MeasTCM control file and correct the DISKCONVERTTO first parameter.
95
DISKCONVERTTO required if mixed DISK types are present.
Cause
Measure data file contains mixed disk types.
Effect
The program terminates. No CSV files are produced.
MeasTCM Termination Messages 209