Tandem Logon Manager for IBM Systems (ILOGMGR) Manual
Error and Informational Messages
A-8 127335—Tandem Logon Manager for IBM Systems (ILOGMGR) Manual
Error Messages and Sense Codes
T0025
plu-name
is the name of the PLU associated with the logon error.
slu-name
is the name of the SLU associated with the logon error.
error-code
is a unique Tandem error code and its associated sense data.
sense-data
is the sense data associated with the Tandem error code.
The error codes listed below describe user-recoverable actions. If you encountered an
error code that does not appear on the list, contact your Tandem representative with the
error code you encountered.
LF0008, %H08120007
Cause. MAXLUS on the PU is too small.
Effect. The logon request is rejected.
Recovery. Increase the size of MAXLUS.
LF0012, %H084F0000
Cause. The Creator was not started.
Effect. The logon request is rejected.
Recovery. Start the Creator.
LF0013, %H084F0000
Cause. One of the following may be the cause:
•
No Creator application was defined
•
The LU does not exist
•
The LU with PROTOCOL LOGON does not exist
Effect. The logon request is rejected.
Recovery. To recover, do one or more of the following:
1. Define the Creator application
T0025 - LOGON ERR - PLU=plu-name, SLU=slu-name,
TANDEM CODE=error-code, sense-data