TCP/IP (Parallel Library) Configuration and Management Manual
SCF Error Messages
HP NonStop TCP/IP (Parallel Library) Configuration and Management Manual—522271-006
B-4
PTCPIP 00016
Effect. The command is not executed.
Recovery. Use the RECSIZE parameter while starting a trace. When a larger trace
record size is used, there is less chance of trace records being truncated.
PTCPIP 00016
Cause. This occurs when a Primary command is rejected because at least one subnet
is still in the started state and switching to another CPU. This takes any started subnets
out of service.
Effect. The command is not executed.
Recovery. Try moving the LAN access interfaces to TCP/IP subsystem backup CPU
first.
PTCPIP 00017
Cause. Device selected for subnet not available between the same CPU pair as the
TCP/IP process.
Effect. The command is not executed.
Recovery. Select a device that is available between the same CPU pair as the TCP/IP
process or stop the TCP/IP process and restart it specifying a CPU pair that has
access to the device.
PTCPIP 00018
Cause. Physical access to the device does not exist. Either the device is not installed
or a failure has occurred.
Effect. The command is not executed.
Recovery. Select a device that is available or correct the problem.
PTCPIP 00019
Cause. Incorrect device name specified.
PTCPIP 00016 Primary not allowed, some subnets still in
STARTED state.
PTCPIP 00017 Device access not available from same CPU as
TCPMAN.
PTCPIP 00018 Device access not available from any CPU.
PTCPIP 00019 Unknown LIF device name.