TCP/IPv6 Configuration and Management Manual (G06.29+, H06.03+, J06.03+)
SCF Error Messages
HP NonStop TCP/IPv6 Configuration and Management Manual—524523-012
C-4
Effect. The command is not executed.
Recovery. Use the RECSIZE parameter while starting a trace. When a larger trace
record size is used, there is less chance of trace records being truncated.
TCPIPV6 00015
Cause. This error occurs when a multiple CPU halt is caused by a SNAX issue. The
first coldload fails because the operator selects an incorrect SYSnn.
Effect. The default gateway for the TCP/IP will not be loaded.
Recovery. To resolve this issue, restart TCP/IPv6 subsystem.
TCPIPV6 00016
Cause. This occurs when a Primary command is rejected because at least one
SUBNET is still in the started state and switching to another CPU. This takes any
started SUBNETs out of service.
Effect. The command is not executed.
Recovery. Try moving the LAN access interfaces to TCP/IP subsystem backup CPU
first.
TCPIPV6 00017
Cause. Device selected for SUBNET not available between the same CPU pair as the
TCP/IP process.
Effect. The command is not executed.
Recovery. Select a device that is available between the same CPU pair as the TCP/IP
process or stop the TCP/IP process and restart it specifying a CPU pair that has
access to the device.
TCPIPV6 E00015 Object #ZPTM*.GW1 Already Defined.
TCPIPV6 E00016 Primary not allowed, some subnets still in
STARTED state.
TCPIPV6 E00017 Device access not available from same CPU as
TCPMAN.