Time Synchronization User's Guide
HP NonStop Time Synchronization User’s Guide  Page 64 of 81 
1002: TimeSync version started 
TimeSync started successfully. 
version 
is the version of TimeSync; for example, 1.0.126. 
Cause. TimeSync was started on the system. 
Effect.  TimeSync begins processing. 
Recovery. Not applicable. 
1003 
1003: TimeSync could not initiate operations; shutting down 
TimeSync could not initiate operations with the communication layer, and is shutting 
down as a result. This error only occurs during startup. 
Cause. TimeSync could not obtain a network connection, therefore it could not start 
successfully. 
Effect.  TimeSync does not start. 
Recovery. Check to be sure that all network infrastructure is up and running (network 
device drivers, TCP/IP processes/daemons, etc.), and ensure that TimeSync is not 
configured to use a LocalPort that is currently being used by a different application. 
1004 
1004: TimeSync shutting down due to error 
TimeSync encountered an internal error during normal processing that it could not 
recover from, and is shutting down as a result. 
Cause. An internal processing or resource error occurred from which TimeSync could not 
recover. 
Effect.  TimeSync shuts down. 
Recovery. Check the system log and/or TimeSync log for additional messages detailing 
the specific cause of the error. 